Air Stripping Towers Single-Source Responsibility for Packing, Sanitherm, an established designer, manufacturer and supplier of Air Stripping Towers, has added the availability of a complete line of COLUMN INTERNALS providing SINGLE SOURCE RESPONSIBILITY to its product line. Working with "LANTEC PRODUCTS INC." we have incorporated the most efficient internal packing available today. |
LIQUID DISTRIBUTORS
Designed to Satisfy a Broad Range of Operating Conditions
| Pictured at the right is a typical liquid distributor with single parting
box and weir troughs. Liquid loading, gas loading and column diameter will dictate the
number of parting boxes and weir troughs. Construction is such that pressure drop is
minimized - normally .25" WC or less. All liquid distributors are designed to be supported from a circumferential ring supplied as an integral part of column. Distributor furnished in sections, suitable for installation through manway of specified dimension (normally 24"). Assembly hardware included. |
![]() |
![]() |
Pictured at the left is a typical liquid
distributor designed to provide excellent water distribution over a wide turn down ratio.
Note the multiple risers, orifices and drip tubes assuring gas and liquid separation,
hence minimum pressure drop is .25" WC or less. Construction permits installation through manway of specified dimension (normally 24"). Hardware, leveling clamps and gasketing included. |
| The collector distributor pictured at the right may be used when multiple packing sections are incorporated in the column design. Risers are generous in cross section and adequately covered preventing the entrance of water and assuring a free flow of air. Pressure drop is minimized to .25" WC or less. | ![]() |
PACKING SUPPORTS
| MULTI BEAM GAS INJECTED (MBGI) PACKING SUPPORT | |
![]() |
This design offers almost 100% open area,
hence minimum pressure drop is .1/.15" WC. MBGI packing support construction allows installation through the manway - manway size to be specified (normally 24"). All necessary assembly hardware including leveling clamps provided. MBGI support mounts on a circumferential ring furnished as an integral part of column. MBGI normally self supporting. |
| SIMPLE GRID SUPPORT WITH OPEN AREA 75/80% PRESSURE DROP .45" WC The design permits installation through the manway,
the size to be specified by the column designer, normally 24". All necessary assembly
hardware included. |
![]() |
Available Materials of
Construction |
TOWER PACKING SPECIFICATIONS
| The tower packing material shall be 3.5" LANPAC®, as
manufactured by LANTEC PRODUCTS, INC. in Agoura Hills, California. The packing product
shall be produced from virgin polypropylene material and shall be a symmetrical
configuration with a nominal diameter of about 3.5" and shall have a minimum of
30,000 liquid dripping points in each cubic foot. The surface elements of the packing
shall be evenly spaced throughout the packing structure to effectuate a uniform
distribution of both liquid and gas flows through the packing section. The packing product
shall have superior wetting characteristics so as to prevent plugging or solids build-up
on the packing surfaces as well as to enhance the mass transfer capabilities of the
packing. The packing shall have a geometric surface area of 44 ft2/cu.ft., a void fraction of 92.5% and a packing factor of 14 (1/ft.). The "Packing Factor/Surface Area" ratio shall not exceed 0.318. The pressure drop through the packing shall not exceed 0.22 inches of equivalent water column head per foot of packing depth, at a liquid loading rate of 10,000 lbs/hr/ft2 and a gas loading rate of 1,500 lbs/hr/ft2.